http://rctronics.com/late_builder.php
Faceplate Builder

Order by: Part or Name

ADA/Lift Interlock
Air Conditioner Controller
Documents:
RCT-01748-00000 Air Conditioner Control.pdf

FAN SPEED  +12 VDC.  Provides power to all fan speeds, high, medium and low.

CONDENSER +12 VDC. Provides power to clutch and condenser.

Fan High "coil" input 12 VDC @ .150 ampere. Output 70 ampere @ 12 VDC. Protected with fuse or circuit breaker F1

Fan Medium "coil" input 12 VDC @ .05 ampere. Output 30 ampere @ 12 VDC. Protected with fuse or circuit breaker F2.

Fan Low "coil" input 12 VDC @ .05 ampere. Output 30 ampere @ 12 VDC. Protected with fuse or circuit breaker F3.

Clutch "coil" input 12 VDC @ .05 ampere. Output 30 ampere @ 12 VDC. Protected with fuse or circuit breaker F4.

Condenser "coil" input 12 VDC @ .150 ampere. Output 70 ampere @ 12 VDC. Protected with fuse or circuit breaker F5.

NOTE: Negative connection with 16 AWG.

NOTE: Size all conductors to accommodate all loads and supply feeders.

NOTE: When condenser  fuse opens the clutch output will be removed.

Ambulance Type II Electrical Control System
KIT-01755-00000       Includes the following:

RCT-01755-00000     Plug-N-Play Power Center.

RCT-01894-00700     Dash 10 Switch Panel Staged Lighting.

RCT-01895-00700     Patient 12 Switch Panel Staged Lighting.

DAT-01350-00200     Dash Panel to Power Center.                   

DAT-01758-00150     Patient Panel to Power Center.  

DAT-01757-00200     A/C Heat Fan Switch to Thermostat.                           

DAT-01345-07200     Door Open Indicator to Power Center.

DAT-01347-01020     Power Center to ABC Body Flasher.

DAT-01348-01820     Dash Code Light to Patient Panel Code Switch.  

RCT-MOLEX-00011    Molex Connector Kit; complete for harness wires

Ambulance Type II Electrical Control System
KIT-01755-00001       Includes the following:

RCT-01755-00000     Plug-N-Play Power Center.

RCT-01940-00700     Dash 11 Switch Panel Staged Lighting.

RCT-01935-00700     Patient 14 Switch Panel Staged Lighting.

DAT-01350-00200     Dash Panel to Power Center.                   

DAT-01758-00150     Patient Panel to Power Center. 

DAT-01757-00200     A/C Heat Fan Switch to Thermostat.                           

DAT-01345-07200     Door Open Indicator to Power Center .

DAT-01347-01020     Power Center to ABC Body Flasher.

DAT-01348-00200     Dash Code Light to Patient Panel Code Switch.  

RCT-MOLEX-00011    Molex Connector Kit; complete for harness wires.

Ambulance, Auto Sequencer.
Documents:
RCT-00498-00000 Sequence, Eight Zone.

This is a daughter control which plugs into the mother board, PCB-00745, Dash Switch.

Requires fifteen Conductor data cable, DAT-01350-00006.

Ambulance, Aux. Power Card
Documents:
RCT-01563-00000 Ambulance, Aux. Power Card.

Adds four circuits to the Ambulance Power Center, RCT-01479.

When ordering this control the switching (RCT-01564) must be ordered as well. Switches that can be used. "ON-OFF-ON" or "ON-OFF". Either maintained or momentary. When using "ON-OFF-ON" switch , two of the four power relays on the Aux. Power Card, RCT-01563 will be used.

Ambulance, Body Flasher, ABC
Documents:
RCT-00772, ABC Body Flasher.

Ambulance Body Flasher, ABC. 

Connects to J3 of Ambulance Power Center RCT-00743, Barrier Strip or RCT-01479, Plug-In-Play. 

Please order data cable, DAT-01346-00XX0, "XX" determines lenght in feet.

COPY & PASTE",  DAT-01346-00XX0 into, SEARCH, for rapid locate and selection of data cable.

Ambulance, Eight Zone Light Control.
Documents:
RCT-00450-00000 External Compartment Control.

External Compartment Light Control, Eight Zone. 

Connects to J4 of Ambulance Power Center RCT-00743, Barrier Strip or RCT-01479, Plug-In-Play. 

Please order 3 conductor data cable, DAT-01346-00XX0, "XX" determines lenght in feet.

COPY & PASTE",  DAT-01346-00XX0 into, SEARCH, for rapid locate and selection of data cable.

Ambulance, Load Manager
Documents:
RCT-01076-00000 Load Manager.

This is a daughter control which plugs into the mother board, PCB-00745, Dash Switch.

Ampere Display
Ampere Meter 200 Ampere.
AMPERE, VOLTAGE & HOUR METER with Faceplate
Audio Selector
Documents:
RCT-00669-00000 Audio Selector.

Two Channel Audio Selector.
Auto Sequencer.
Documents:
RCT-00498-00001 Sequence, Eight Zone.

Sequencer, can be used in, "Stand Alone Applications". Provides eight zone negative outputs.
Automatic Ignition Lock
Documents:
RCT-01662 Automatic Ignition Lock.pdf

Control allows engine operation with ignition key removed.

Momentairy depressing "ARM" switch bypasses the ignition switch and permits ignition key removal.

An unauthorized operator operating the "BRAKE" will reset the control causing the engine to stop.

Additionally a set of form C "ALARM CONTACTS" will operate which may be connected to a horn or siren.

Reset is accomplished with "SILENCE" switch.

Automatic Signal Switcher
Documents:
RCT-553 Auto Signal Switcher Booklet.pdf

Automatic Signal Switcher.
Auxiliary Module 6 Switch
Battery Charge Protect Indicator
BATTERY IGNITION
Brake, Turn, Backup Light Monitoring Control.
Documents:
RCT-01725-00000 Brake, Turn and Backup Light Monitor.pdf

 

Control provides inputs from; "Backup Light", "Left Turn", "Right Turn", "Brake Light" and "Spare Input".

Control outputs; "Backup Light", "Left Turn", "Right Turn", "Brake Lights (4 outputs) and "Spare Output". Current monitioring of all loads will show bulb failure.

RCT-01730 Display, is remotely mounted for driver identification of bulb failure.

Required cable: DAT-01349-00XX0 (XX depicts length)

 

Showing ( 41 to 60 ) of 253